Sign In | Join Free | My qualitytoyschina.com
China Guangdong Zhufeng Electric Co., Ltd. logo
Guangdong Zhufeng Electric Co., Ltd.
Verified Supplier

1 Years

Home > Motor Soft Starters >

Energy Saving RS485 soft Motor Soft Starters Controller 250KW-16000KW

Guangdong Zhufeng Electric Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Energy Saving RS485 soft Motor Soft Starters Controller 250KW-16000KW

  • 1
  • 2

Brand Name : ZFeng

Model Number : ZF-R Series

Certification : CE、CB、CCC、ISO9001、ISO14001、ISO45001、EN61439、EN61000

Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram

Supply Ability : 500-10000 per Month

Delivery Time : 3 days

Packaging Details : Carton and Plywood box packaging

Voltage : 3.6kV ~ 12kV

Power : 250 ~ 16000KW

Operating Voltage : AC/DC 220V

Soft Stop Time : 0 ~ 30s

Current : According to Motor Power and Load

Modbus : RS-485

Noise : less than 70dB

Contact Now

ZF-R Series Energy-Saving Motor Soft Starter

An energy-saving soft starter is an electrical control device that combines motor soft start technology with energy-saving control functions. It aims to reduce the inrush current during motor startup while optimizing operating parameters to achieve energy-saving goals.


I. Working Principle

Energy-saving soft starters control the conduction angle of power electronic devices (such as thyristors, IGBTs, etc.) to gradually adjust the voltage and current applied to the motor, enabling smooth acceleration during startup and avoiding the inrush current generated by traditional direct startup methods. Additionally, the built-in energy-saving algorithms dynamically adjust motor operating parameters based on load variations to reduce energy consumption under light or no-load conditions.

II. Main Functions

  1. Soft Start Function
    • Reduces current surge during motor startup through voltage ramp or current-limiting startup methods, extending the lifespan of motors and mechanical equipment.
  2. Energy-Saving Control Function
    • Light-Load Energy Saving: Reduces voltage or adjusts power factor during light or no-load conditions to minimize reactive power losses.
    • Intelligent Speed Regulation (available in some models): Automatically adjusts motor speed based on load demand to avoid unnecessary energy consumption.
    • Power Factor Compensation: Improves the motor's power factor during operation, reducing reactive power losses in the power grid.
  3. Protection Function
    • Built-in protection against overload, overvoltage, undervoltage, phase loss, and overheating to ensure safe operation of motors and equipment.
  4. Monitoring and Communication Function
    • Some high-end models support real-time monitoring of motor operating status (e.g., current, voltage, power) and communication interfaces (e.g., Modbus, CAN) for connection to upper-level computers or PLCs, enabling remote monitoring and centralized management.

III. Application Fields

Energy-saving soft starters are widely used in the following areas:

  • Industrial Sector: Starting and energy-saving control of heavy-duty equipment such as fans, pumps, compressors, and conveyors.
  • Construction Sector: Energy-efficient operation of air conditioning systems, water supply systems, and elevators.
  • Energy Sector: Starting and protection of large equipment in oil fields, mines, and power plants.
  • Infrastructure: Energy management of public facilities such as traffic lights, pump stations, and sewage treatment plants.

IV. Energy-Saving Effects

Energy-saving soft starters achieve energy savings through the following methods:

  • Reducing Startup Losses: Traditional direct startup methods generate inrush currents 5-7 times the rated current, whereas soft starters limit the startup current to 2-3 times the rated current, reducing startup losses.
  • Lowering No-Load Losses: During no-load or light-load conditions, voltage reduction or power factor adjustment minimizes reactive power losses.
  • Optimizing Operating Efficiency: Dynamically adjusting motor operating parameters based on load demand prevents motors from running inefficiently for extended periods.

V. Product Features

  • High Efficiency: Comprehensive energy-saving rates can reach 10%-30%, depending on load characteristics and operating environments.
  • High Reliability: Utilizes advanced power electronics and intelligent control algorithms to ensure long-term stable operation.
  • Easy Installation: Compact size and lightweight design support wall-mounted or DIN rail installation, facilitating field retrofits.
  • Low Maintenance: Modular design and self-diagnostic functions reduce maintenance costs.

VI. Selection Guidelines

  1. Choose Based on Load Characteristics
    • For square torque loads such as fans and pumps, prioritize soft starters with energy-saving functions.
    • For loads requiring speed regulation, consider variable frequency drives (VFDs) or soft starters with speed regulation capabilities.
  2. Pay Attention to Energy-Saving Certifications
    • Select products that have passed national energy-saving certifications or comply with relevant industry standards (e.g., IEC, GB).
  3. Consider Expandability
    • Choose models with communication interfaces and remote monitoring capabilities based on future needs for system integration.

Product Tags:

RS485 Motor Soft Starters

      

250KW Motor Soft Starters

      

RS485 soft start motor controller

      
Quality Energy Saving RS485 soft Motor Soft Starters Controller 250KW-16000KW wholesale

Energy Saving RS485 soft Motor Soft Starters Controller 250KW-16000KW Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangdong Zhufeng Electric Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)